Silver/silver chloride reference electrodes consist of silver coated with silver chloride by thermal or electrolytic methods. They provide high stability and are used directly in seawater or brackish river water. Silver/silver chloride/potassium chloride electrodes are used in other applications, including steel in concrete.
Marine electrodes are protected by robust housings with holes for electrolyte contact. They must be immersed in seawater for several hours before use to stabilise. Cable ends are carefully insulated to prevent short circuits.
When not in use, some types must be stored in saturated potassium chloride solution as recommended by their manufacturer. Potential measurement accuracy in seawater is approximately ±5 mV, considered very high.
Borna Electronic can design and manufacture silver/silver chloride reference electrodes to meet customer requirements or project needs.